1910.29(2)(v) Is erected as close to the work area as the task permits; and Unsafe railings can be required to be repaired or replaced as a condition of insuring the loan. OSHA requires: Handrails must provide an adequate handhold for employees to grasp to prevent falls. 1910.29(h)(4) Performs climbing duties as a part of routine work activity. The minimum clearance between handrails and any other object is 2.25 inches (5.7 cm). Do not polish or wax your staircase. Step Guardrail Height: Unlike ADA guidelines, the guardrails in OSHA steps also act as the handrails when the top edge of the guardrail is between 36 and 38 inches above the leading edge of the stair tread. When guardrail systems are used at hoist areas, a removable guardrail section, consisting of a top rail and midrail, are placed across the access opening between guardrail sections when employees are not performing hoisting operations. 1910.29(f)(7) Strength criteria. To keep apprised of such developments, you can consult OSHA's website at http://www.osha.gov. Handrails must be between 36 inches and 38 inches (if built prior to January 2017, the height limitation is between 30 inches and 38 inches) as measured from the leading edge of the stair tread — the nosing – to the top surface of the handrail. 1910.29(b)(7) The ends of top rails and midrails do not overhang the terminal posts, except where the overhang does not pose a projection hazard for employees. 1910.29(g)(1) Cages and wells installed on fixed ladders are designed, constructed, and maintained to permit easy access to, and egress from, the ladder that they enclose (see Figures D-14 and D-15 of this section); Just because a railing exists doesn't mean it will pass FHA standards. The top rail must be at least 42 inches in height (§1910.29 (f) (1) (ii) (B)) and the handrail must be 30 to 38 inches in height (§1910.29 (f) (1) (i)) (as measured at the leading edge of the stair tread to the top surface of the rail). Richard E. Fairfax, Director 1910.29(1)(ii)(B) The height of stair rail systems installed on or after January 17, 2017 is not less than 42 inches (107 cm) from the leading edge of the stair tread to the top surface of the top rail. Handrails shall be provided on at least one side of closed stairways preferably on the right side descending. Mr. Helmut Haydll At least one handrail One stair rail system with handrail on open side. When the top edge of a stair rail system also serves as a handrail, the height of the top edge must be no more than 37 inches (94 cm) nor less than 36 inches (91.5 cm) from the upper surface of the stair rail to the surface of the tread. Install strong safety gates for babies and young kids. Stairs are a safety concern in both residential and commercial construction. According to OSHA requirements for stairs, employers must install stair rails on stairs with four or more risers or a height higher than 30 inches, whichever is less. 1910.29(h)(1) Is physically capable, as demonstrated through observations of actual climbing activities or by a physical examination, to perform the duties that may be assigned, including climbing fixed ladders without fall protection; (c) The top of stair railings, handrails and handrail extensions installed on or after April 3, 1997, shall be at a vertical height between 34 and 38 inches above the nosing of treads and landings. Must have a toe board 42 inch minimum height Required if 48 inches or greater drop from walking surface — top rail, intermediate rail and posts Intermediate rail at “about halfway up” Must have a … OSHA, however, opened a rulemaking proceeding in 1990 to revise Subpart D of Part 1910, including the current height requirements for stair railings and handrails. 1910.29(2)(i) Has a minimum breaking strength of 200 pounds (0.89 kN); Sincerely, Make sure your staircase is well lit. 1910.29(2)(ii) Is installed so its lowest point, including sag, is not less than 34 inches (86 cm) and not more than 39 inches (99 cm) above the walking-working surface; Consider carpeting your stairs. One word on terminology: Stair railing and stair guards, though they may sound like the same thing, are different. 1910.29(1)(ii) The perimeter of the designated area is delineated with a warning line consisting of a rope, wire, tape, or chain that meets the requirements of paragraphs (d)(2) and (3) of this section. 1910.29(f)(4) in stair rails. 1910.29(1)(i) Employees remain within the designated area while work operations are underway; and OSHA Guardrail & Handrail Requirements Employers must provide guardrails along any exposed edge of walking-working surfaces 4' or higher, according to OSHA regulations. The following requirements apply to all stairways as indicated: (1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with: (A) At least one handrail; and (B) A stair rail consisting of a top rail and mid-rail along each unprotected side or edge. To keep apprised of such developments, you can consult OSHA's website at https://www.osha.gov. 1910.29(g)(4) Platforms used with fixed ladders provide a horizontal surface of at least 24 inches by 30 inches (61 cm by 76 cm). The top-edge height of a guardrail may exceed 45 inches if it … 1910.29(a)(1) Ensure each fall protection system and falling object protection, other than personal fall protection systems, that this part requires meets the requirements in this section. Make sure your stairs are up to code. The employer may use chains or gates instead of a removable guardrail section at hoist areas if the employer demonstrates the chains or gates provide a level of safety equivalent to guardrails. 1910.29(1)(ii)(A) The height of stair rail systems installed before January 17, 2017 is not less than 30 inches (76 cm) from the leading edge of the stair tread to the top surface of the top rail; and Toeboards may be omitted around vehicle repair, service, or assembly pits when the employer can demonstrate that a toeboard would prevent access to a vehicle that is over the pit.